Appendix B: TPP0
500 and TPP1000 500 MHz and 1 GHz 10X Passive Probes Information
Safety Summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied. Using the probe or accessories in a manner not specied
could result in a shock or re hazard.
To Avoid Fire or Personal Injury
Ground-Referenced Oscilloscope Use. Do not oat the reference lead of this probe when using with ground
referenced oscilloscopes (for example, DPO, MSO , and TDS series oscilloscopes). The reference lead must be connected to
earth poten
tial (0 V).
Connect and Disconnect Properly. Connect the probe output to the measurement instrument before connecting the
probe to the circuit under test. Disconnect the probe input and the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid Electric Shock. To avoid injury or loss of life, do not connect o r disconnect probes or test leads while they
are conne
cted to a voltage source.
Observe All Terminal Ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before making connections to the product.
Avoid Electric Shock. When using probe accessories, never exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and voltage rating.
Avoid Electric Overload. To avoid injury o r re hazard, do not apply potential to any input, including the reference
inputs, that varies from ground by more than the maximum rating for that input.
Avoid
Exposed Circuitry and Do not Operate Without Covers.
Do not touch exposed connections and
components when power is present.
Inspect The Probe And Accessories. Before each use, inspect probe and accessories for damage (cuts, tears,
defects in the probe body, accessories, cable jacket, etc.). Do not use if damaged.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Sa
fety Terms and Symbols Terms in This M anual.
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
MDO4000 Series Oscilloscopes User Manual 189

Table of Contents

Other manuals for Tektronix MDO4104-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4104-3 and is the answer not in the manual?

Tektronix MDO4104-3 Specifications

General IconGeneral
BrandTektronix
ModelMDO4104-3
CategoryTest Equipment
LanguageEnglish

Related product manuals