General
Compressor Belt driven, multi cylinder, wobble plate type driven
by the truck engine (Model 10) and by the truck
engine or electric motor. (Model 20)
Engine Compressor Oil Charge 6 oz (177 ml) in compressor
Total system: 12 oz (355 ml)
Electric Standby Compressor Oil Charge 6 oz 177 ml) in each compressor
Total system: 24 oz (710 ml)
Compressor Oil Type Polyol Ester P/N 203-413
Defrost Method:
Truck Engine Operation Model 10 Hot gas
Model 20 Hot gas
Electric Standby Model 20 Hot gas
Defrost Timer: Initiation Interval Adjustable, 1 hour to 10 hours
Termination interval 45 minutes
R-134A REFRIGERATION SYSTEM
Refrigerant Charge and Type 5 lb (2.3 kg) R-134a
Defrost Termination Switch: Opens 52 F (11.1 C)
Closes 42 F (5.6 C)
Liquid Line Injection Switch: Opens 200 ± 5 F (93 ± 3 C)
Closes 230 ± 5 F (110 ± 3 C)
High Pressure Cutout Switch: Opens 350 + 25/-0 psi (2413 + 172/-0 kPa)
Closes 200 ± 20 psi (1379 ± 138 kPa)
Low Pressure Cutout: Opens 5 to 11 in. Hg vacuum (-17 to -34 kPa)
Closes 4 to 7 psi (28 to 48 kPa)
Condenser Fan Pressure Switch: Opens 130 ± 10 psi (896 ± 69 kPa)
Closes 180 ± 10 psi (1241 ± 69 kPa)