26 Translation of the original instruction
4.2 Check Table B program
B-1
4.2.1 Check the battery
Instant UpRight specifications require this procedure to
be executed every 250 hours or quarterly, whichever
comes first.
The battery condition is good for normal mechanical
performance and safe operation. Improper electrolyte
liquid and damaged
cables and wiring may cause
damage to parts and hazards.
Risk of electric shock / burn. Exposure to live circuits
can result in death or serious injury. Remove all rings,
watches and other accessories.
The risk of physical injury. Batteries contain acidic
substances. Avoid overflow or contact with acidic
substances in the battery. With hydrogenated sodium
and water to neutralize the overflow of the battery
acid.
1.
Wear protective clothing and wear protective
glasses.
2.Ensure that the wiring of the battery cable is not
corroded.
Note: Adding a terminal protector and anti-corrosion
sealant will help eliminate corrosion of the battery
terminals and cables.
3.Models without maintenance-
free or sealed
battery: to ensure that the battery fixed firmly, the
cable wiring fastening. Proceed to step 4. Model with
maintenance-free or sealed battery: Make sure the
battery is securely fastened and the cable is
tightened. Proceed to step 12.
4.Allow the battery to fully charge and leave for at
least 6 hours.
5.Remove the battery vent cover and check the
specific gravity of each battery unit with a liquid
hydrometer. Write down the results.
6.Check the ambient air temperature and adjust
the specific gravity of each unit according to the
following:
a. Increase the reading of each unit by 0.004 for
each additional 5.5 ° C above 26.7 ° C.
b. Reduce the reading of each unit by 0.004 for
each reduction of 5.5 ° C below 26.7 ° C.
Result: All battery cells show an adjusted specific
gravity of 1.277 or higher. The battery is full. Proceed
to step 11.
Result: One or more battery cells show a specific
gravity of 1.217 or less. Proceed to step 8.
7.Make sure that the battery is balanced or fully
charged and allowed to stand for at least 6 hours.
8.Remove the battery vent cover and check the
specific gravity of each battery unit with a liquid
hydrometer. Write down the results.