4.4.4 Test Function Pump
Instant UpRight
specification requires this procedure to be executed every 1000 hours or annually, whichever
comes first.
Functional pump operation is normal for safe vibration operation and machine operation are essential.
NOTE: This procedure is executed on a rugged, horizontal surface and the platform is in stowed position,
when the platform extension table is fully indented.
1.Lower the platform to the stowed position.
2.Turn the key switch to the ground controller and pull the red "emergency stop" button on the ground and
platform controller to the ON position.
3.On the ground controller, record the time it takes to completely lift the platform.
Result: The time taken to completely raise the platform is equal to or less than the time shown in the
table below. The efficiency of the pump is good.
X2047 32s
X2647 45s
X3247 55s
X3947 61s
X4647 80s
Note: If the above time cannot be reached, the machine must be marked and the machine must be stopped
before repairing or replacing the pump.
The dangers of tipping. Failure to follow the instructions to repair or replace the pump will affect the stability
of the machine, and even lead to death or serious injury.