29 “Translation of the original instruction”
B-3
4.2.3
Check Tire, Wheel and Groove Nut
Torque
Instant UpRight specifications require this procedure to
be executed every 250 hours or quarterly, whichever
comes first.
Maintain tires and wheels to keep
condition, as well as suitable wheel fastener torque, is
critical for safe operation and good machine
performance. Damage to tires and / or wheels may
cause the machine to tipping over. Failure to detect
problems and repair in time may also cause damage to
machine parts.
1.
Check the tire surface and sidewall for incisions,
cracks, perforations and abnormal wear.
2.Check the wheels for damage, bending and cracks.
3.
Remove the slotted nut opening pin and check
whether the torque of each groove nut is suitable.
CAUTION: When removing the groove nut or checking
the groove nut torque, be sure to replace the cotter
pin.
4.Check whether each lug bolt torque is appropriate.
5.Install a new cot and secure it.
B-4
4.2.4 Test Emergency Stop
Instant UpRight specifications require this procedure
to be executed every 250 hours or quarterly,
whichever comes first.
A functioning emergency stop system is very
important for the safe operation of the machine.
Incorrect operation "Emergency stop" button can not
cut off the power and stop all functions of the
machine, which will lead to dangerous situations.
NOTE: In the case of safety considerations, in
addition to the red "emergency stop" button on the
platform, you can also choose to operate the ground
controller instead of the platform controller.
1.Turn the key switch to the ground controller and
pull the red "emergency stop" button on the ground
controller and platform controller to the ON
position.
2.
Push the red "emergency stop" button on the
ground controller to the OFF position.
Result: All functions of the machine should not
operate.
3.Turn the key switch to the platform controller and
pull the red "emergency stop" button on the ground
controller and platform controller to the ON
position.
4.Push the red
"emergency stop" button on the
platform controller to the OFF position.
Result: All functions of the machine should not
operate.
Note: Even if the key switch is turned to the
platform controller, the ground controller's
"emergency stop" button can also stop all machine
work.