High Pressure Shutoff Threshold: Value to be used as the maximum acceptable
pressure threshold value if using the High and/or Low Pressure Shutoff options. Valid
values range from 0.0-28.0 for each option; however, the values most follow a logical
value range for each succeeding option. Low Pressure Shutoff Threshold should be less
than or equal to the Low Pressure Warning Threshold which should be less than or equal
to the High Pressure Warning Threshold which should be less than or equal to the High
Pressure Shutoff Threshold value.
HHD Notes Tab
The HHD Notes Tab displays a list of the current pre-defined note codes that are available
to the meter reader on the HHD. This list will control the pre-defined notes that are available
on all the HHDs. Changes to this list will only take effect on the HHD the next time the unit is
loaded.
Add: The Add button allows you to add a notecode to the list of pre-defined note codes.
It is necessary to highlight one of the existing note codes before this button will become
active. When Add is pressed, you are prompted for a note reference number (seen to
the left of the note text on the screen), the note text, and whether or not you would like
to include this note in the export file if it is entered by the meter reader. In some cases,
there will be certain notes (or none of them) that would be desirable to export to billing
(for example, if the billing system generates work orders based on note codes). The
meter reader can add free form notes at any time (as long as the Enable Text Notes
option is checked on the HHD tab), but pre-defined notes can only be added to the
system here.
Modify: The Modify button allows you to modify an existing pre-defined note code in
the system. Highlight the note that needs to be modified, click the Modify button, and
change the text description in the box provided.
Note:
If modifying a note, only the Text and Include in Export options may be changed. If you
wish to change the note number as well, it is necessary to delete the note entirely and
add in a new one.
Delete: The Delete button allows you to delete an existing pre-defined note code in the
system. Highlight the desired note code, and click the Delete button.
3 Polling Devices | 39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem sensus AutoRead and is the answer not in the manual?

Xylem sensus AutoRead Specifications

General IconGeneral
BrandXylem
Modelsensus AutoRead
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals