EasyManuals Logo
Home>Zapi>Inverter>ACE3

Zapi ACE3 User Manual

Zapi ACE3
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
AFFZP0BB – ACE3 – User Manual Page – 11/139
2.4 Functional features
- Speed control (three versions available: sensored, sense coil and sensorless as
explained in the introduction section).
- Optimum behavior on a slope due to the speed feedback: the motor speed
follows the accelerator, starting a regenerative braking if the speed exceeds the
setpoint.
- Electrical stop on a ramp (the machine is electrically hold on a slope) for a
programmable time.
- Stable speed in every position of the accelerator.
- Regenerative release braking based on deceleration ramps: regenerative
braking when the accelerator pedal is partially or fully released.
- Direction inversion with regenerative braking based upon deceleration ramp.
- Regenerative braking and direction inversion without contactors: only the main
contactor is present.
- Release-braking profile modulated by an analog input, as to obtain a
proportional-brake feature.
- Increased resolution of the speed control at low speed.
- Voltage boost at the start and with overload to obtain more torque (with current
control).
- Integrated driver for an electromechanical brake.
- Hydraulic-steering function:
a) Traction inverter:
- The traction inverter sends a "hydraulic-steering function" request to the
pump inverter on the CAN bus line.
- If the pump inverter is not present (for ex: tractor application), the
traction inverter can manage a "hydraulic-steering function" by driving a
hydro contactor which drives an hydraulic-steering motor.
b) Pump inverter:
- The pump inverter manages a "hydraulic-steering function": it drives the
pump motor at the programmed speed for the programmed time.
- High efficiency of motor and battery due to high frequency commutations.
- Double microcontroller for safety functions.
- Self-diagnosis, the faults can be monitored through the Console or through Zapi
MDI/Display.
- Modification of parameters through the programming console.
- Internal hour-meter that can be viewed from the console.
- Memory of the last five alarms with relative hour-meter and temperature
displayed on the console.
- Test function within the Console for checking the inverter parameters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ACE3 and is the answer not in the manual?

Zapi ACE3 Specifications

General IconGeneral
BrandZapi
ModelACE3
CategoryInverter
LanguageEnglish

Related product manuals