EasyManuals Logo
Home>Zapi>Inverter>ACE3

Zapi ACE3 User Manual

Zapi ACE3
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
AFFZP0BB – ACE3 – User Manual Page – 87/139
Error code Effect Condition
Restart
procedure
CAN
OPEN
CODE
MDI
CODE
ZAPI
CODE
LED
CODE
VDC LINK OVERV.
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Stand-by, running
Valves or
Traction/Pump
Request
0XFFCA 77 202 77
EB is applied,
Traction/Pump, valves
stopped
re-cycle
SEAT MISMATCH
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up, stand-by,
running
Valves or Traction/
Pump request
0xFFDE 15 222
15
LOGIC FAILURE #1
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Stand-by, running
Valves or
Traction/Pump
Request
0x5114 19 19 19
LOGIC FAILURE #2
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
Valves or
Traction/Pump
Request
0XFF12 18 18 18
LOGIC FAILURE #3
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by
Valves or
Traction/Pump
Request
0XFF11 17 17 17
LC COIL OPEN
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
Request
0xFFE6 22 230 22
IQ MISMATCHED Traction is stopped Running
Valves or
Traction/Pump
Request
0xFFF5 24 245 24
INIT VMN LOW 01
INIT VMN LOW 02
INIT VMN LOW 03
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up Key re-cycle 0x3121 30 207 30
INIT VMN HIGH 81
INIT VMN HIGH 82
INIT VMN HIGH 83
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up
Key re-cycle
0x3111 31 206
31
VMN HIGH
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by
Valves or
Traction/Pump
Request
0x3110 31 31 31
VMN LOW
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up
Valves or
Traction/Pump
Request
0x3120 30 30 30
HW FAULT 11
HW FAULT 12
HW FAULT 13
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up Key re-cycle 0xFFE3 32 227 32
HW FAULT 01
HW FAULT 02
HW FAULT 03
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up Key re-cycle 0xFFE3 32 227 32
POSITIVE LC OPEN
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
running
Key re-cycle 0xFFD5 35 213 35
FIELD ORIENT KO
MC is opened, EB is
applied, Traction/Pump,
valves stopped
Running
Valves or
Traction/Pump
0xFFFD 36 253 36