OCR Programming
254
Enable/Disable US Currency Serial Number
Parameter # 683 (SSI # F1h ABh)
To enable or disable US Currency Serial Number, scan one of the following bar codes.
OCR Orientation
Parameter # 687 (SSI # F1h AFh)
Select one of five options to specify the orientation of an OCR string to be read:
• 0
o
to the imaging engine (default)
• 270
o
clockwise (or 90
o
counterclockwise) to the imaging engine
• 180
o
(upside down) to the imaging engine
• 90
o
clockwise to the imaging engine
• Omnidirectional
Setting an incorrect orientation can cause misdecodes.
NOTE: OCR is not as secure as a bar code. To decrease OCR misdecodes and speed OCR reading, set an
accurate OCR template and character subset, and use a check digit. See OCR Subset on page 257 and OCR
Template on page 259.
NOTE: All OCR fonts are disabled by default. Enabling OCR can slow bar code decoding. Enabling more than
one OCR font could also slow OCR decoding and impact OCR decoding accuracy.
Enable US Currency
*Disable US Currency