HVC 450 kW E-Bus Charger Installation Guide
Revision: 1.2 COMPANY CONFIDENTIAL
Date released: 16-08-2018 Page 11 of 128
1.4.3. Electric hazards
Hazardous voltage
The HVC 450 kW E-Bus Charger conductors under hazardous electrical
voltages. The grid terminals on the internal DIN rail may carry hazardous
voltages, even if all circuit breakers are switched off.
1.4.4. Installation safety
Personal safety (PPE)
Always wear a safety helmet, safety gloves and safety shoes when you
do the lifting and tilting work.
Visually examine the package for damage. See section Before unpacking
on Page 53 and section Before unpacking on Page 82. If there is
damage, do not install the system.
Hazardous voltage
Instructions:
1. Always switch off the external group switch and the main switch in
the cabinet, before performing any installation, disassembly, repair
or replacement of components.
2. Do a voltage check and make sure that the electrical power is
disconnected from the system.
3. Only ABB certified technicians are permitted to commission the HVC
450 kW E-Bus Charger.
4. When the system is in an open or dangerous condition, do not allow
unqualified persons to go near it. Instruct and warn people about the
potential harmful high voltages.
5. The installation and maintenance personnel must supply their own
lighting equipment, since the HVC 450 kW E-Bus Charger has no
lights inside the cabinet.
6. Always connect the Protective Earth (GND or PE) first, before
connecting the neutral (N) and Phase (P) wiring.
7. Correctly lock the door after installation or service operations.
Make sure that there is a minimum free space of 39.37 Inch in front of
the door of the Power Cabinet. The minimum space is necessary to allow
service personnel to quickly move away from the Power Cabinet if there
is an emergency when the door is open.