HVC 450 kW E-Bus Charger Installation Guide
Revision: 1.2 COMPANY CONFIDENTIAL
Date released: 16-08-2018 Page 74 of 128
A Terminal block
B AC utility power cable
1. Move the cable towards the terminal block (A).
2. Strip 0.43 Inch of the insulation from the ends of the wires.
3. Crimp a ferrule onto the end of the wire.
4. Loosen the connector screws.
5. Insert the wires into the connectors, see table below:
6. Tighten the connector screws.
5.8.3. Connect the Interlock cable
Interlock cable connection in the slave 2 HVC 150S:
A Terminal block
B Interlock cable from/to slave 1 HVC 150S
1. Move the cable towards the terminal block (A).
2. Strip 0.43 Inch of the insulation from the ends of the wires.
3. Crimp a ferrule onto the end of the wire.
4. Loosen the connector screws.
5. Insert the wires into the connectors, see table below:
Interlock In (slave 1 HVC 150S)
Interlock Out (slave 1 HVC 150S)
See also Appendix H Signal connection diagram.
6. Tighten the connector screws.