Page #50 background image
HVC 450 kW E-Bus Charger Installation Guide
Revision: 1.2 COMPANY CONFIDENTIAL
Date released: 16-08-2018 Page 50 of 128
Data and control cables
Functional
description
ASC control
cable
ACS heater
cable
ACS CP/PE
cable
EMO cable
Distance
sensor
cable
Beacon light
cable
WiFi cable
Number of
cross
12
3
2
4
4
4
1
Twisted pair
No
No
No
No
No
No
Coaxial
Cross section
14 AWG
14 AWG
16 AWG
20 18
AWG
20 18
AWG
20 18
AWG
Min Max
external
diameter to fit
through gland
0.51 0.83
Inch
0.20 0.39
Inch
0.20 0.39
Inch
0.20 0.39
Inch
0.20 0.39
Inch
0.20 0.39
Inch
inapplicable
Shielding
No
No
Yes (tinned
copper
braid)
No
No
No
Yes (tinned
copper braid)
Conductor
Fine strand
copper wire
Fine strand
copper wire
Fine strand
copper wire
Fine strand
copper wire
Fine strand
copper wire
Fine strand
copper wire
Fine strand
or solid
copper wire
Insulation
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or
other
material that
can be used
outdoor and
are UV-
protected
PVC or other
material that
can be used
outdoor and
are UV-
protected
Characteristic
impedance
50
Frequency
range
0.3 GHz - 6
GHz
Test Voltage
2 kV
2 kV
2 kV 4 kV
2 kV 4 kV
2 kV 4 kV
2 kV 4 kV
Nominal
Voltage Uo/U
600/1000
Vac
600/1000
Vac
300 Vac or
600 Vac
300 Vac or
600 Vac
300 Vac or
600 Vac
300 Vac or
600 Vac
Ambient
Temperature
range
-40ºC to
80ºC
-40ºC to
80ºC
-40ºC to
80ºC
-40ºC to
80ºC
-40ºC to
80ºC
-40ºC to
80ºC
-40ºC to
80ºC
Core
identification
Numbering
Numbering
Numbering
Numbering
or color
Numbering
or color
Numbering
or color
Coaxial
Remarks
Including on
both side N
(male)
connectors
All cables must have and isolation that are self-extinguishing and flame retardant
according to UL VW-1, CSA FT1.
All cables must be meet the UL and the RoHS compliance.
4.5. Internet connection
In most cases the integrated 3G modem is used for wireless internet access. A customer SIM
card is not required. If there is no 3G signal available, a standard wired internet connection is
required. For this option, contact ABB Sales department (see Contact information on Page 13
for contact details).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HVC and is the answer not in the manual?

ABB HVC Specifications

General IconGeneral
BrandABB
ModelHVC
CategoryBattery Charger
LanguageEnglish

Related product manuals