Section-2
04-3004_S2_OPM_ABB_POWERSCALE_10-50kVA_EN_150113.doc Page 1/15 ABB
Printed in Switzerland – Modifications reserved
CONTENTS SECTION-2
2.1 BLOCK DIAGRAM ....................................................................................................................................... 2
2.1.1 WIRING AND BLOCK DIAGRAMS ...................................................................................................... 2
2.1.2 RECOMMENDED CABLE SECTIONS & FUSE RATINGS ................................................................. 2
2.1.2.1 Cabinet A (10-15-20 kVA) & Cabinet B (10-15-20-25 kVA) terminal connections overview ............ 2
2.1.2.2 Cabinet C (25-30 kVA) terminal connections overview .................................................................... 2
2.1.2.3 Cabinet C (40-50 kVA) terminal connections overview .................................................................... 3
2.1.3 CONNECTION DIAGRAM POWERSCALE ......................................................................................... 4
2.2 FRONT and REAR VIEW ............................................................................................................................. 5
2.2.1 FRONT AND REAR VIEW OF POWERSCALE CABINET A ............................................................... 5
2.2.1.1 Front and Rear View PowerScale 10-20kVA in Cabinet A and Connection Terminals ................... 5
2.2.2 FRONT AND REAR VIEW OF POWERSCALE CABINET B ............................................................... 6
2.2.2.1 Front and Rear View PowerScale 10-25kVA in Cabinet B and Connection Terminals ................... 6
2.2.3 FRONT AND REAR VIEW OF POWERSCALE CABINET C ............................................................... 7
2.2.3.1 Front and Rear View PowerScale 25-50kVA in Cabinet C and Connection Terminals ................... 7
2.3 BATTERY CONNECTIONS ......................................................................................................................... 8
2.3.1 BATTERY BANKS CABINETS A, B, C AND EXTERNAL BATTERY .................................................. 8
2.3.1.1 Examples of Battery Autonomy at full load with standard battery cabinets
and standard battery configuration ................................................................................................... 9
2.3.1.2 Connection of External Battery for PowerScale ............................................................................. 13
2.3.1.3 Terminals for External Battery connection .................................................................................... 13