140 34980A User’s Guide
4 Low Frequency Multiplexer Switch Modules
34923A Simplified Schematic for Two- or Four-Wire Mode
This drawing shows two independent 20- channel 2- wire MUXes.
To change configuration modes, use the
SYSTem:MODule:WIRE:MODE
command.
HL
HL
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
021
022
023
024
025
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
H
L
H
L
H
L
H
L
ABus2
DMM
(SENS)
ABus3
ABus4
923
913 914
924922
912911
921
ABus1
DMM
(MEAS)
HL HL HL H L
L
H
L
H
L
H
L
H
L
HL
L
H
LHLHLHLH
HL
HL
HL H L
H
LH
100Ω 100Ω
100Ω
100Ω
100Ω
100Ω
100Ω
100Ω
100Ω
100Ω
100Ω 100Ω
Bank 1
Bank 2
COM 1
COM 2
Analog Buses
NOTE: The three-digit number assigned to each switch represents the channel number.
NOTE:
Bank Relays: Reed non-latching
Analog Bus Relays: Armature
non-latching

Table of Contents

Other manuals for Agilent Technologies 34980A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 34980A and is the answer not in the manual?

Agilent Technologies 34980A Specifications

General IconGeneral
BrandAgilent Technologies
Model34980A
CategorySwitch
LanguageEnglish

Related product manuals