RF Multiplexer Switch Modules 7
34980A User’s Guide 203
Example: Clearing the cycle count for a relay The following command resets
the cycle count on the channels 103 and 201 for a module in slot 1.
Note that clearing the cycle count on a specific channel will clear the
count on all three relays in the corresponding bank.
DIAGnostic:RELay:CYCLes:CLEar (@1103,1201)
Example: Resetting module to power-on state The following command resets
a module in slot 4 to its power- on state.
SYSTem:CPON 4
34941A and 34942A Simplified Schematic
Both the 34941A and 34942A modules are configured alike. They each
contain four banks of latching switches. Each bank consists of three form
C relays.
The front panel of the two RF MUX modules are similar with channel
labels in the same positions, the unique product number on the left, and
the product description on the right.
301 302 303 304 404403402401COM COM
101 102 103 104 204203202201COM COM
3494xA
Quad 1x4
RF MUX
xx Ohm
Bank 1 Bank 2
Bank 3 Bank 4

Table of Contents

Other manuals for Agilent Technologies 34980A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 34980A and is the answer not in the manual?

Agilent Technologies 34980A Specifications

General IconGeneral
BrandAgilent Technologies
Model34980A
CategorySwitch
LanguageEnglish

Related product manuals