Getting Started 1
U3402A User’s and Service Guide 23
Performing resistance measurements
Measuring resistance
Seven ranges:
Slow reading rate: 120 .000 W, 1.20000 kW, 12.0000 kW, 120.000 kW, 1.20000 MW, 12.0000 MW,
120.000 MW
Medium reading rate: 400 .00 W, 4.0000 kW, 40.000 kW, 400.00 kW, 4.0000 MW, 40.000 MW,
300.00 MW
Fast reading rate: 400 .0 W, 4.000 kW, 40.00 kW, 400.0 kW, 4.000 MW, 40.00 MW, 300.0 MW
Measurement method: 2-wire ohms or 4-wire ohms, open circuit voltage limited to < 5 V
Input protection: 500 V on all ranges
1 Press . The default function is 2- wire W measurement.
2 Connect the red and black test leads to the input terminal as shown in
Figure 1- 15 or Figure 1- 16 on page 24 respectively (according to the
selected measurement method).
3 Probe the test points (by shunting the resistor) and read the display. In
auto- ranging mode, the multimeter automatically selects the appropriate
range and the measurement is displayed.
CAUTION
Disconnect circuit power and discharge all high-voltage capacitors before measuring
resistance to avoid damaging the multimeter or the device under test.

Table of Contents

Other manuals for Agilent Technologies U3402A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies U3402A and is the answer not in the manual?

Agilent Technologies U3402A Specifications

General IconGeneral
BrandAgilent Technologies
ModelU3402A
CategoryMultimeter
LanguageEnglish

Related product manuals