EasyManuals Logo
Home>Allen-Bradley>Touch terminals>PanelView Plus 1000

Allen-Bradley PanelView Plus 1000 User Manual

Allen-Bradley PanelView Plus 1000
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Publication 2711P-UM001A-EN-P
6-2 Terminal Connections
Logic Controller Cable
Charts
Refer to the following charts for a summary of PanelView Plus
terminal connections to controllers and network interface modules.
Runtime Communication Cables - To Controllers
Note 1: 2711P-CBL-EX04 can be used for direct connections only
Note 2: 1784-CP14 can be used for direct connections only
Cables: PanelView Plus to Processor
Protocol PanelView Plus Comm Port
SLC-500, 5/01, 5/02
CH1 RJ45
(DH-485)
SLC-5/03, 5/04, 5/05
CH0 (9-pin RS-232)
(DF1 or DH-485)
SLC 5/03
CH1 (RJ45)
(DH-485)
SLC 5/04
CH1 (DH+)
SLC 5/05
CH1 (ENET)
DF1
(any)
RS-232 (DF1) Comm Port (9-pin)
PanelView Plus 700 -1500 N/A
2711-NC13 (16ft/5m)
2711-NC14 (32ft/10m)
2706-NC13 (10ft/3m)
N/A N/A N/A
DH-485 Serial
(any)
RS-232 (DH-485) Comm Port (9-pin)
PanelView Plus 700 -1500
use AIC+ Module
(1761-NET-AIC)
Connect to Port 1 or 2
2711-NC13 (16ft/5m)
2711-NC14 (32ft/10m)
2706-NC13 (10ft/3m)
use AIC+ Module
(1761-NET-AIC)
Connect to Port 1 or 2
N/A N/A
DH-485
xxx6xx
DH-485 Communication Port
PanelView Plus 700 -1500
2711P-xxx6xx
1761-CBL-AS03
(10ft/3m)
1761-CBL-AS09
(30ft/9m)
use AIC+ Module
(1761-NET-AIC)
Connect to Port 3
1761-CBL-AS03
(10ft/3m)
1761-CBL-AS09
(30ft/9m)
**Note 1**
N/A N/A
EtherNet/IP
(any)
EtherNet/IP Comm Port
PanelView Plus 700 -1500
N/A
Use 1761-NET-ENI Module with
Ethernet cable
N/A N/A
2711P-
CBL-EX04
Ethernet
Crossover
Cable
**Note 2*
Remote I/O
xxx6xx
Remote I/O Communication Port
PanelView Plus 700 -1500
2711P-xxx6xx
SLC 5/02 only
use 1747-SN with
shielded twinaxial cable
use 1747-SN Module with shielded twinaxial cable
DHPlus
xxx6xx
DH+ Communication Port
PanelView Plus 700 -1500
2711P-xxx6xx
N/A N/A N/A
shielded
twin axial
cable
N/A
IMPORTANT
You must configure the Channel 0 Port of the SLC
5/03, 5/04, 5/05 controller for DH-485
communications using the RSLogix 500 (AI500
software).

Table of Contents

Other manuals for Allen-Bradley PanelView Plus 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PanelView Plus 1000 and is the answer not in the manual?

Allen-Bradley PanelView Plus 1000 Specifications

General IconGeneral
BrandAllen-Bradley
ModelPanelView Plus 1000
CategoryTouch terminals
LanguageEnglish

Related product manuals