cleaning & Maintenance
COMBITHERM® CT PROFORMANCE™ SERIES • STEP-BY-STEP PROCEDURES • MN-35948 • 48.
MOBILE EQUIPMENT RESTRAINT FOR GAS MODELS
The gas Combitherm must use a connector that
complies with The Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69 CSA 6.16 and
addenda Z21.69a-1989. A quick disconnect device
must be installed to comply with The Standard for
Quick Disconnect Devices for Use with Gas Fuel,
ANSI Z21 CSA 6.9. and European Standard EN203.
Adequate means must be provided to limit the
movement of this appliance. Limitation of movement
must be made without depending on the connector,
the quick disconnect device, nor the associated
piping designed to limit appliance movement. If it
becomes necessary to disconnect the restraint, it must
be reconnected immediately following the return of
the appliance to its original position.
1. Install a manual gas shut-off valve along with an
approved disconnect device.
2. Install an A.G.A. certified, heavy-duty connector
that complies with ANSI Z 21.69 or
CAN 1-6.10m88 along with a quick-disconnect
device in compliance with ANSI Z21.41 or
CAN 1-6.9m70. Connectors must be installed
with a cable restraint to prevent excessive tension
from being placed on the connector.
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
MOBILE EQUIPMENT RESTRAINT FOR ELECTRIC MODELS
Any appliance that is not furnished with a
power supply cord but includes a set of casters
must be installed with a tether. Adequate means
must be provided to limit the movement of this
appliance without depending on or transmitting
stress to the electrical conduit. The following
requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3. Such mobile appliances or appliances on
mobile stands must be installed with the use
of a flexible connector secured to the
building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. A flexible connector is
not supplied by nor is it available from the factory.