Wiring Diagrams
21.9 Single-Stage, Single-Phase Unit with Optional Components, CT Motor, and Electric Heat
Fig. 37 Single-Stage, Single-Phase Unit with Optional Components, CT Motor, and Electric Heat
DWG No.
DRAWN BY: DATE REV
PART No.
E-MAIL:
1 STAGE - 1 PHASE - CT MOTOR
2 THROUGH 6 TONS CAPACITY
FZA 4/11/2024 2CL111009
UPM I - OPTIONS - EH
8 733 838 096
LUG
GROUND
UNIT
C
OY RG
24
EMS
RV
BMR
DPS
AUX
LWV
HGV
LWV
FACTORY WIRE
FIELD WIRE
OPTIONAL COMPONENTS LEGEND:
[ ] A2L - AIR TO LIQUID REFRIGERANT LEAK SENSOR
[ ] A2R - A2L BLOWER RELAY
[ ] AUX - AUXILIARY RELAY
(FOR LOOP PUMP, ETC)
[ ] BMR - BLOWER MONITOR RELAY
[ ] CBR - 24V CIRCUIT BREAKER (75VA & 100VA ONLY)
[ ] CMR - COMPRESSOR MONITOR RELAY
[ ] DPS - DIFFERENTIAL PRESSURE SWITCH
[ ] DS - DISCONNECT SWITCH
[ ] EMS - ENERGY MGMT SYSTEM RELAY
[ ] HGV - HOT GAS VALVE SOLENOID
[ ] HSL - HIGH TEMPERATURE SUCTION LIMIT
(WITH HOT GAS BYPASS ONLY)
[ ] LWV - LEAVING WATER VALVE
[ ] MBV - MOTORIZED BALL VALVE
UPM STATUS LED - BLINK CODES
1
HIGH PRESSURE FAULT
2 LOW PRESSURE FAULT
3 CONDENSER FREEZE CONDITION
4 CONDENSATE OVERFLOW FAULT
5
BROWN OUT FAULT
6 EVAPORATOR FREEZE CONDITION
7 REFRIGERANT LEAK
GROUND
BLK (COM)
TRANSFORMER
CC
T1
L1
T2
L2
L1 L2
DS
CAP
COMP
C
R
S
NOTES:
1. SEE UNIT NAME PLATE FOR ELECTRICAL RATING.
2. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH
N.E.C.-N.F.P.A. #70, COPPER CONDUCTORS ONLY - CONDUCTEURS EN CUIVRE SEULEMENT.
3. 208/230V UNITS ARE FACTORY WIRED FOR 230V OPERATION. FOR 208V OPERATION,
REMOVE PRIMARY LEAD FROM 240 TERMINAL AND CONNECT IT TO 208. CAP ALL UNUSED TERMINALS.
4. FOR ALTERNATE EMS COIL VOLTAGES CONSULT FACTORY.
5. UPM-I INCLUDES BUILT IN: 270-300 SECOND RANDOM START
300 SECOND DELAY ON BREAK
120 SECOND LOW PRESSURE BYPASS
6. "TEST" DIP SWITCH REDUCES DELAYS TO 10 SEC WHEN SET TO YES. MUST BE SET TO "NO" FOR NORMAL
OPERATION.
7. "FREEZE SENSOR" ON CONDENSER WILL BE SET TO 25°F OPERATION BY DEFAULT, IF 15°F OPERATION IS REQUIRED,
MOVE DIP SWITCH SLIDER TO THE 15°F POSITION.
8. "ALARM OUTPUT" DIP SWITCH MUST BE SET TO "PULSE" IF BLINKING T-STAT SERVICE LIGHT IS DESIRED OR IF DDC
CONNECTION IS AVAILABLE. CONT FOR NON BLINKING THERMOSTAT CONNECTION.
9. DEFAULT SETTINGS FOR UPM BOARD FROM FACTORY SHOWN. ALSO SEE INSTALLATION MANUAL.
10. ALARM OUTPUT IS NORMALLY OPEN (NO) DRY CONTACT. IF 24 VAC IS NEEDED, CONNECT R FROM TERMINAL BLOCK
TO ALR-COM TERMINAL, 24VAC WILL BE SENSED ON THE ALR-OUT WHEN THE UNIT IS IN ALARM CONDITION.
OUTPUT WILL BE PULSED IF PULSE IS SELECTED.
11. REVERSING VALVE NOT PRESENT ON UNITS WITH STRAIGHT COOL.
12. REFER TO UNIT IOM FOR FACTORY DEFAULT MOTOR SPEED INSTALLATION SETTINGS AND AVAILABLE PROGRAMMED
SPEED PINS.
13. A2R WILL ONLY BE PRESENT WHEN OPTIONAL A2L SENSOR IS CONNECTED.
14. DUAL RESET PRIMARY CONTACTS WILL OPEN AT 145°F (+/-5°F) AND CLOSE AT 105°F (+/-9°F). BACK UP
CONTACTS WILL OPEN AT 185°F (+/-8°F). BACK-UP CONTACTS WILL NOT RESET IN AMBIENT TEMPERATURES ABOVE
-31°F.
3
21
H
SEE MOTOR TERMINAL
CONNECTIONS BELOW
ECM TERMINAL CONNECTIONS
N - L2
G - GROUND
L - L1
C - 24V COMMON
1-5 - SPEED TAPS
N
G
L
C
34
5
HIGH VOLTAGE
MOTOR CONNECTIONS
1
2
RD
BK
BK
SEE NOTES 5 - 10
LED1
EC
BC
OPTION CARD
OFF
LED2
LED3
LED4
H
O
Y
R
LED5
LED6
LED7
LED8
Y_OUT
G_OUT
O_OUT
W_OUT
LED9
LED10
H_OUT
E_OUT
-30F
100F
20 50
-30F
100F
20 50
POT
HEAT_SP
POT
COOL_SP
G_OUT
Y_OUT
R
C
H
O
Y
H2O
E_OUTH_OUT
W_OUTO_OUT
RH
EWTS
BK
BK
W
1
2
3
MBV
11
YLBL
YL
OR
OR
GY
OR YL
WT
RD
RD
GN
BL
YL
RD
BK
YL
BL
BL
RD
RD
BL
RD
BK
OR
BL
GY
GN
BL
GN
RD
BK
BM
BK
WT
GN
BL
GN/YL
USE CLASS II FIELD WIRING
G_Out
G
C
OUT
COM
POWER
UNIT PROTECTION MODULE
STATUS
R
R
ALARM
FREEZE1
FREEZE2
COND
LPC
HPS
CC
LOCKOUT 4 2
RESET R Y
ALARM CONT PULSE
TEST YES NO
FREEZE1 15F 25F
FREEZE2 15F 25F
PUMP YES NO
GND
TO
DDC
OR
THERMOSTAT
CS
FS2
FS1
LPS
HSL
VT
CC
CMR
BN
BN
BL
BN
BK
WT
GN/YL
A2L
Y
HPS
HPS
YL
BL
HC
HC
BK
RD
HC
EHR
EHR
3
9
BL
BL
WT
STANDARD COMPONENTS LEGEND:
BM - BLOWER MOTOR
CAP - COMPRESSOR CAPACITOR
CC - COMPRESSOR CONTACTOR
CS - CONDENSATE SENSOR (IN DRAIN PAN)
FS - FREEZE SENSOR
EHR - ELECTRIC HEATING/BLOWER RELAY
HC - HEATING CONTACTOR
HE - HEATING ELEMENT
HLS - HEATING LIMIT SWITCH
HPS - HIGH PRESSURE SWITCH
LPS - LOW PRESSURE SWITCH
RV - REVERSING VALVE (HEAT PUMPS)
A2R
3
9
HLS1
HE1
RD
BK
HLS2
HE2
RD
BK
14
14
A2R
GN
13
BL
ECM TERMINAL CONNECTIONS
12
A2R
47
13
RD
WT
ELECTRIC HEAT
ELEMENTS
kW HE1 HE2
5 HLS1
7.5 HLS1 HLS2
10 HLS1 HLS2
GN
24VAC BY OTHERS
4
CBR
RD
BL
CLASS II POWER SUPPLY
TRANSFORMER
EHR
2
8
EHR
4
7
FOR REFERENCE ONLY Actual unit wiring may vary from this
example. Always refer to the wiring diagram attached to the unit.
80 |
CL Series Heat Pumps — 8733838716 (2024/05)