218/263 Bosch Rexroth AG | Tightening Technology 3 608 870 A47
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2017-
9.8.4.4 IPM
Settings Data IPM
Use this menu item to define the setting for communication with Rexroth IPM Protocol of the Nexo cord-
less Wi-Fi nutrunner.
Each work sequence (AFO) is represented by one line in the AFO table, see table 9–70. In the AFO table,
an unlimited number of AFOs can be inserted and deleted.
Table 9–69: IPM tab
Element Description
Active Tick this checkbox to enable communication with Rexroth IPM Protocol.
IPM IP address IP address of the IPM gateway to which the data are to be sent (target ad-
dress).
IPM port IP port of the IPM gateway to which the data are to be sent (target address).
Value range: 0 - 65535
Default setting: 5501
ID code mask The IPM data set has different (text) data fields to which flexible parts of the
ID code can be mapped. The maximum number of characters that can be en-
tered is 255.
This element can be used for this purpose, with the following characters be-
ing allowed for the ID code mask (IDCodeMask):
–_
Placeholder; character at this position is ignored
–*
New placeholder character to provide a clearer view
–I
Character at the position marked by I is taken over in IPM ID code
IP code data The IPM data set has different (text) data fields to which flexible parts of the
ID code can be mapped. The maximum number of characters that can be en-
tered is 255.
This element can be used for this purpose, with the following characters be-
ing allowed for ID code data (IDCodeKeys):
–A
AFO extension field
–V
Fields for process number
–B
Fields for component carrier ID
–T
Fields for component type designation/type number
–Z
Additional ID
IPM version Version of the IPM protocol that is used for transmission.
The version must comply with the version supported by the IPM gateway
used.
AFO Work sequences (definitions of the individual entries per work sequence, see
table 9–70)
–Add
Inserts a new AFO
Add Loosen
Adds a new AFO, based on the selected channel for program 99 ("Loos-
en")
–Remove
Deletes an AFO
Save Click Save to save the edited data.
Discard Click Discard to discard the edited data.
Basic settings All settings in this tab are reset to the factory setting.