■ Backing up Service Mode
Each device is tuned at the time of shipment and the tuned values are written on the service label.
Because setting values and management data of the host machine are stored in the eMMC of the Main Controller PCB, they
need to be backed up before replacing the Main Controller PCB.(Do not remove the eMMC PCB form Main Controller PCB.)
Also, restoration of the backup data is necessary after replacing the Main Controller PCB.
Backup: Connect a USB memory device to the USB memory port.
7. Service Mode
130