To configure internal clock source for the protect controller, use the following commands:
enable
configure terminal
controller sonet 0/4/6
sts-1 3
vtg 1 t1 1 clock source internal
vtg 1 t1 1 framing esf
end
Configuring VT 1.5-T1 Loopback
To configure VT 1.5-T1 loopback, use the following commands:
enable
configure terminal
controller sonet 0/5/0
rate oc3
no ais shut
alarm- report all
framing sonet
clock source internal
sts-1 1
clock source internal
mode vt-15
vtg 1 t1 1 loopback local
end
Configuring VT 1.5-T1 BERT
To configure VT 1.5-T1 BERT, use the following commands:
enable
configure terminal
controller sonet 0/5/0
rate oc3
no ais shut
alarm- report all
framing sonet
clock source internal
sts-1 1
clock source internal
mode vt-15
vtg 1 t1 1 bert pattern 2^11 interval 10
end
Configuring Path Overhead
This section describes the configuration of path overhead.
C2 Flag
To configure the C2 flag, use the following commands:
enable
configure terminal
controller sonet 0/5/0
sts-1 1
overhead c2 10
end
J1 Flag