CHAPTER 8
Specifications
• Chassis Specifications, on page 117
• Power Supply Specifications, on page 122
• Chassis and Module Power and Heat Values, on page 130
• Weight Specifications, on page 131
Chassis Specifications
Catalyst 9404R Switch Chassis Specifications
Table 8: Physical Specifications of the Chassis
SpecificationItem
10.47 x 17.3 x 16.3 inches (26.53 x 43.94 x 41.40
cms)
Dimensions (H x W x D)
6 RURack units (RU
3
)
Chassis with fan tray—39.0 lbs (17.2 kgs)Weight
3
The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45
mm).
Table 9: Environmental Specifications of the Chassis
SpecificationItem
• 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)
• 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)
Ambient temperature and
altitude for normal
operations
4
• 23° to 131°F (-5 to +55ºC), up to 6,000 feet (1800 m)
• 23° to 122°F (-5 to +50ºC), up to 10,000 feet (3000 m)
Nonoperating and storage: -40° to 167°F (-40° to 75°C)
Ambient temperature and
altitude for short-term
5
exceptional conditions
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
117