The 23-inch rack mount kit consists of the following items:
Table 7: Contents of 23 Inch Rack Mount Kit
Parts DescriptionQuantity
Rack Mounts2
M4 Phillips pan-head screws6
12-24 x 3/4-inch Phillips binder-head screws6
Rack-Mounting the Chassis in a NEBS-Compliant Mode
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to
ensure that the system remains stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the
heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the
unit in the rack.
Statement 1006
Warning
Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018
Warning
To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended
ambient temperature of:
40°C. Statement 1047
Warning
Before you begin
Prepare for the installation as follows:
• Place the chassis on the floor or on a sturdy table as close as possible to the rack. Leave enough clearance
to allow you to move around the chassis.
• Open the rack-mount kit and verify that all parts are included.
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
67
Installing the Switch
Rack-Mounting the Chassis in a NEBS-Compliant Mode