InteliLite
NT
AMF20/25, SW version 2.2, ©ComAp September 2014 6
IL-NT-AMF-2.2-Reference Guide.pdf
Text
PAGE (Capital letters in the frame) buttons on the front panel
Break Return (Italic) set points
Generator protections (Bold) Set point group
REMOTE START/STOP (Capital letters) binary inputs and outputs
*Something (Symbol * before text) valid only for IL-NT AMF 25
Note:
ComAp believes that all information provided herein is correct and reliable and reserves the right to
update at any time. ComAp does not assume any responsibility for its use unless otherwise expressly
undertaken.
Note:
SW and HW must be compatible (e.g. IL-NT-AMF25 firmware and IL-NT AMF25 HW) otherwise the
function will be disabled. If wrong software is downloaded, message HARDWARE INCOMPATIBLE
appears on controller screen. In this case download correct software and use Boot jumper
programming close Boot jumper and follow instructions in LiteEdit or follow video guide “Boot
Jumper Programming“ at http://www.comap.cz/support/training/training-videos/.
WARNING VERY IMPORTANT !!!
Every time you want disconnect following InteliLite
NT
controller terminals:
Mains voltage measuring and / or
Binary output for MCB control and / or
MCB Feedback
Switch InteliLite to MAN or OFF Mode or disconnect the Binary outputs Starter and
Fuel to avoid unexpected automatic start of gen-set and GCB closing.
!!! CAUTION !!!
Dangerous voltage
In no case touch the terminals for voltage and current measurement!
Always connect grounding terminals!
In any case do not disconnect InteliLite
NT
CT terminals!
Adjust set points
All parameters are preadjusted to their typical values. But the set points in the “Basic settings” settings
group !!must!! be adjusted before the first startup of the gen-set.
!!! WRONG ADJUSTMENT OF BASIC PARAMETERS
CAN DESTROY THE GEN-SET !!!
The following instructions are for qualified personnel only. To avoid personal injury do
not perform any action not specified in this User guide !!!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp intelilite nt amf25 and is the answer not in the manual?

ComAp intelilite nt amf25 Specifications

General IconGeneral
BrandComAp
Modelintelilite nt amf25
CategoryController
LanguageEnglish

Related product manuals