To enable the C4000 to operate as desired two things must be set:
1. Configuration (K Factor) Switch Settings
Refer C4000 Set-Up K Factor Switch Settings (see page 21)
This switch accesses different options that must be set appropriately for the
particular type of dispenser.
2. Parameter Switch Settings
Refer Parameter Switch (see page 33)
This switch is used to conduct the Display Segment Test, set price (product
density - if a bulkmeter or LPG), and set pump number. Also, when the
C4000 is configured for 'Comcard', 'Compin', or 'CWIDKey' the parameter
switch is used for card/pin/key validation and for setting the card/key
system number
The C4000 pump/dispenser software, the configuration code (used to set
the pump/dispenser to single, dual or multi mode) has been extended to 5
digits. When configuring the pumps/dispensers, the litre display will display
each digit.
For FUTRA software configuration options, see the FUTRA
service supplement.
Multi-hosed Pump/Dispenser with LPG
An MPD with LPG is configured by setting digits 5=3 and 4=5.
With COM125 magnetic or Bennett meters, to set LPG compensation and
motor spirit without correction, set digit 1=4.
For COM125 optical meters when motor spirit correction is required as well,
set digit 1=6.
Refer Setting the Configuration Code (see page 16)
Setting the Configuration Code
Refer to Figure 3. While setting the configuration code, the price display
shows 'C' and the volume display shows 'XXXXX'.