On PIN Pad Dot
Matrix Display (if
Connected)
Card not read properly, try re-swiping. In addition, C4000 may be configured for
the wrong card reader track, or the card or card reader could be faulty.
Pump no longer communicating with Central Controller.
The full-colon on the display indicates that the processor supply has been OFF
and back ON since the last transaction.
Card not validated for the pump/dispenser fuel grade set.
Incorrect card used or the controller has the incorrect access code or ISO number
set. Or requires setting for a particular Card Type.
Card expiry date is earlier than controller date
Algorithm check sum on cards is invalid
An incorrect or invalid pin has been entered.
The network encoded on the card is invalidated in the controller.
Temperature probe out of range. (Only displayed when temperature setting
selected on K Factor Switch). Probe either faulty or not connected.
Fault on Secure PIN pad Processor PCB- replace complete PIN pad.
Fault on Secure PIN pad processor PCB replace complete PIN pad.
The air cut-out switch has operated.
LPG ONLY. Flow rate fell to between 0 and 6 litres/min for more than 6 seconds.
Indicates creepage due to presence of vapour.