Displaying and Printing Totals
Displaying and Printing Totals
To display litre and dollar totals for any single hose on a pump/dispenser,
make sure all nozzles are hung up. Then, for pumps/dispensers:
With Preset: Press either the Cancel or the Fill button, on the hoses'
respective Preset, five or more times and the totals will appear on the
displays.
Without Preset: Remove the nozzle from its holster and hold the nozzle
switch in for five seconds. Then press the nozzle switch rapidly five or
more times - ensuring that the switch 'clicks' each time. The five digit
whole dollar and litre totals will then be shown on the display for ten
seconds.
This is only available on Comcard, Compin, and CWIDKey Basic systems
(i.e. 'b' setting digit 3 = 2)
To access this option the 'b' setting digit 1 must be set to one.
Pump/Dispenser totals are accessed as above, then after displaying the
pump/dispenser total for ten seconds the card/pin/key number and
card/pin/key total will appear. The display will flash for 10 seconds and then
go to the next card/pin/key. All cards/pins/keys with non-zero totals and all
valid cards/pins/keys will be 'scrolled'.
Using a Totals Only - Report
Printer
This is only available on Comcard, Compin, or CWIDKey Basic systems
(i.e. 'b' setting digit 3 = 2.)
Plug the two core cable from the printer into the four pin plug (Red Comms
- Pin 1, Black Comms - Pin 4) on the side of the pump/dispenser. Power up
the printer and make sure it is 'ON LINE'. Then depress the nozzle switch
five or more times - ensuring that the switch 'clicks' each time. The printout
will contain all cards/pins with non-zero totals and all valid cards/pins/keys.
Card/pin/key status is also displayed on this printout.
The printer may also be permanently wired to the C4000 comms. If the
printer is left with the power on and on-line, it will then act as an 'audit trail
printer'. It will then print out the card/pin/key number, litres dispensed and
the total in dollars, at the end of each fill.
All totals mentioned above are non-resettable totals (the only
way they can be cleared is by replacing the C4000 memory IC 'chip').
The displays are only capable of displaying five-digit whole litre totals
(maximum of 99999), but the C4000 memory stores seven digit whole litre
totals (maximum of 9999999.99) for printing
With Central Controller and Futra systems, it is possible to install a receipt
printer either at the pump/dispenser, or at the Central Controller.
The receipt printout includes the following information: Site Number, Pump
Number, Card Number, Reference Number, Date, Time, Product, Litres,
Dollars, Dollars per litre, Odometer Reading (if prompted).