Set-up Modes
No Flow Cut-Off Timer
Compac Industries Ltd.
Page 25
www.compac.co.nz
No Flow Cut-Off Timer
Under normal conditions to end a transaction on a C4000 controlled
pump/dispenser, there are three possibilities:
Returning the nozzle to its holder.
Reaching the preset amount entered.
Cut out on the 'No flow cut-off timer'.
The No Flow Cut-off Timer sets the amount of time the dispenser/pump will
allow a sale to continue after the flow has stopped. The No Flow Cut-off
Timer is terminated if the nozzle is returned to its holster.
The range available is between 1 & 256 seconds. The default setting is
'n0000' (256 seconds).
Setting the No Flow Cut-Off Timer
Refer to C4000 Set-Up K Factor Switch Settings (see page 21).While
setting this value the price display will indicate „n‟ and the volume display
will indicate „nXXXX‟.