D-Link DGS-1100 Series Switch User Manual
The fields that can be configured for SNTP Server Setting are described below:
Parameter Description
IPv4 Address
Enter the IP address of the SNTP server which provides the
clock synchronization.
Click the Apply button to add the SNTP server.
Click the Delete button to remove the specified entry.
Time Profile
This window is used to view and configure the time range settings. The maximum number of time
profiles supported by the switch is 4.
To view the following window, click System > Time Profile, as shown below:
Figure 5-16 Time Range window
The fields that can be configured are described below:
Parameter Description
Range Name
Enter the name of the time range. This name can be up to 8
characters long.
From Week / To Week
Select the starting and ending days of the week that will be
used for this time range. Tick the Daily option to use this
time range for every day of the week. Tick the End Week
Day option to use this time range from the starting day of the
week until the end of the week, which is Sunday.
From Time / To Time
Select the starting and ending time of the day that will be
used for this time range. The first drop-down menu selects
the hour and the second drop-down menu selects the
minute.
Click the Apply button to accept the changes made.
Click the Delete button to remove the specified entry.