Option LHBA (Hydraulic proportional control)
1. Pilot Pressure Gauge Port “X1” ISO 11926-1 9/16-8
2. Start pressure adjustment screw
SAE mounting flange per ISO 3019/1 dimensions (mm [in])
Size 060
SAE 127-4
Size 080
SAE 127-4
Size 110
SAE 152-4
Size 160
SAE 152-4
Size 210
SAE 165-4
Size 250
SAE 165-4
AA
272.3 [10.72] 289.9 [11.41] 316.4 [12.46] 343.8 [13.53]
371.6 [14.63]
390.3 [15.37]
AB
157.4 [6.20] 163.3 [6.43] 167.7 [6.60] 176.4 [6.94]
183.5 [7.22]
189.6 [7.46]
EA
242.6 [9.55] 260.3 [10.25] 286.8 [11.29] 314.00 [12.36]
337.8 [13.3]
357.4 [14.07]
EB
115.0 [4.53] 120.9 [4.76] 138.4 [4.93] 134.0 [5.28]
141.1 [5.56]
147.3 [5.80]
DIN B4 HL mounting flange per ISO 3019/2 dimensions, (mm [in])
Size 060 – DIN 125 Size 080 – DIN 140 Size 110 – DIN 160 Size 160 – DIN 180 Size 210 – DIN 200
AA
247.8 [9.76] 265.9 [10.47] 283.9 [11.18] 311.7 [12.27]
339.6 [13.37]
AB
157.4 [6.20] 163.3 [6.43] 167.7 [6.60] 176.4 [6.94]
183.5 [7.22]
EA
218.1 [8.59] 236.3 [9.30] 254.3 [10.01] 282.1 [11.11]
306.7 [12.07]
EB
115.0 [4.53] 120.9 [4.76] 125.3 [4.93] 134.0 [5.28]
141.1 [5.56]
Size 250 is not available.
Cartridge mounting flange dimensions (mm [in])
Size 060
Cartridge 160
Size 080
Cartridge 190
Size 110
Cartridge 200
Size 160
Cartridge 200
AA
188.1 [7.41] 187.5 [7.38] 201.9 [7.95] 229.3 [9.03]
AB
157.4 [6.20] 163.3 [6.43] 167.7 [6.60] 176.4 [6.94]
EA
158.4 [6.24] 169.1 [6.66] 172.3 [6.78] 199.7 [7.86]
EB
115.0 [4.53] 120.9 [4.76] 138.4 [4.93] 134.0 [5.28]
Size 210 and 250 are not available.
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Dimensions – Controls on H1B motors
132 |
©