Options T1G1, T2G2 – electric two-position control with PCOR and electric BPD
T1 – electric two-position 12 V / de-energized = min. displacement
G1 – with PCOR / with electric 12 V BPD, de-energized BPD = PCOR active at port B
T2 – electric two-position 24 V / de-energized = min. displacement
G2 – with PCOR / with electric 24 V BPD, de-energized BPD = PCOR active at port B
A
B
n
min
max
C5
C6
M4
MB
M5
P006 067
L1
L2
NMA
Where:
A, B Main pressure lines
L1, L2 Drain lines
M4, M5 Gauge port servo pressure
MA, MB Gauge port system pressure
N Speed sensor (optional)
Options T1G1, T2G2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
Displacement versus control signal versus PCOR pressure
P003 409
12 V/24 V
32° PCOR
160 bar
[2321 psi]
300 bar
[4351 psi]
2
1
3
Where:
1 Maximum displacement
2 Minimum displacement
3 Start setting range
Solenoid Data C5 (BPD) and C6 (Two-Position Control)
Description 12 V 24 V
Min. supply voltage
9.5 V
DC
19 V
DC
Max. supply voltage (continuous)
14.6 V
DC
29 V
DC
Nominal coil resistance @ 20 °C [68 °F]
8.4 Ω 34.5 Ω
Recommended input current
1050 mA 500 mA
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
60 |
©
Danfoss | December 2016 11037153 | BC00000043en-US1103

Table of Contents

Other manuals for Danfoss H1B 060

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss H1B 060 and is the answer not in the manual?

Danfoss H1B 060 Specifications

General IconGeneral
BrandDanfoss
ModelH1B 060
CategoryEngine
LanguageEnglish

Related product manuals