Option THHA (Hydraulic two-position control)
26.0 ±0.5
EG
EE
EH
AM
EF
P005 952
X
X
X1
M4
M4
M4 Servo gauge port ISO 11926-1; 9/16 -18UNF-2B
X1 Pilot pressure gauge port ISO 11926-1 9/16-8
SAE mounting flange per ISO 3019/1 dimensions (mm [in])
Size 060
SAE 127-4
Size 080
SAE 127-4
Size 110
SAE 152-4
Size 160
SAE 152-4
Size 210
SAE 165-4
Size 250
SAE 165-4
AM
193.6 [7.62] 206.6 [8.13] 224.1 [8.82] 242.5 [9.55] 257.7 [10.15] 267.3 [10.52]
EE
145.5 [5.73] 155.5 [6.12] 177.8 [7.0] 197.1 [7.76] 216.9 [8.54] 230.6 [9.08]
EF
161.4 [6.35] 174.4 [6.87] 191.9 [7.56] 210.4 [8.28] 225.6 [8.88] 235.2 [9.26]
EG
158.8 [6.25] 168.8 [6.65] 191.1 [7.52] 210.4 [8.28] 230.2 [9.06] 243.9 [9.60]
EH
184.0 [7.24] 196.9 [7.75] 214.4 [8.44] 232.9 [9.17] 248.1 [9.77] 257.8 [10.15]
DIN B4 HL mounting flange per ISO 3019/2 dimensions, (mm [in])
Size 060 – DIN 125 Size 080 – DIN 140 Size 110 – DIN 160 Size 160 – DIN 180 Size 210 – DIN 200
AM
193.6 [7.62] 206.6 [8.13] 224.1 [8.82] 242.5 [9.55] 257.7 [10.15]
EE
121.0 [4.76] 131.5 [5.18] 145.3 [5.72] 165.2 [6.50] 184.9 [7.28]
EF
161.4 [6.35] 174.4 [6.87] 191.9 [7.56] 210.4 [8.28] 225.6 [8.88]
EG
134.3 [5.29] 144.8 [5.70] 158.6 [6.24] 178.5 [7.03] 198.2 [7.8]
EH
184.0 [7.24] 196.9 [7.75] 214.4 [8.44] 232.9 [9.17] 248.1 [9.77]
Size 250 is not available.
Cartridge mounting flange dimensions (mm [in])
Size 060
Cartridge 160
Size 080
Cartridge 190
Size 110
Cartridge 200
Size 160
Cartridge 200
AM
193.6 [7.62] 206.6 [8.13] 224.1 [8.82] 242.5 [9.55]
EE
61.3 [2.41] 53.1 [2.09] 63.3 [2.49] 82.8 [3.26]
EF
161.4 [6.35] 174.4 [6.87] 191.9 [7.56] 210.4 [8.28]
EG
74.6 [2.94] 66.4 [2.61] 76.6 [3.02] 96.1 [3.78]
EH
184.0 [7.24] 196.9 [7.75] 214.4 [8.44] 232.9 [9.17]
Size 210 and 250 are not available.
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Dimensions – Controls on H1B motors
©
Danfoss | December 2016 11037153 | BC00000043en-US1103 | 139