Options TAG1, TAG2 – Pressure Compensator Over Ride and electric BPD
TA – Pressure Compensator Over Ride / Default (high pressure below PCOR pressure = min.
displacement
G1 – with PCOR / with electric 12 V BPD / de-energized BPD = PCOR active at port B
G2 – with PCOR / with electric 24 V BPD / de-energized BPD = PCOR active at port B
Hydraulic schematic
A
B
n
min
max
C5
M4
MB
M5
P006 071
L1
L2
NMA
Where:
A, B Main pressure lines
L1, L2 Drain lines
M4, M5 Gauge port servo pressure
MA, MB Gauge port system pressure
N Speed sensor (optional)
Option TAG1, TAG2
Displacement versus PCOR pressure
P301 329
32°
PCOR
160 bar
[2321 psi]
300 bar
[4351 psi]
1
2
3
Default: High pressure below PCOR pressure = min. displacement
Where:
1 Maximum displacement
2 Minimum displacement
3 Start setting range
Two-position solenoid data C5 (Brake Pressure Defeat)
Description 12 V 24 V
Min. supply voltage 9.5 V
DC
19.0 V
DC
Max. supply voltage (continuous) 14.6 V
DC
29.0 V
DC
Nominal coil resistance @ 20 °C [68 °F] 8.4 Ω 34.5 Ω
Recommended input current 1050 mA 500 mA
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
88 |
©
Danfoss | December 2016 11037153 | BC00000043en-US1103

Table of Contents

Other manuals for Danfoss H1B 060

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss H1B 060 and is the answer not in the manual?

Danfoss H1B 060 Specifications

General IconGeneral
BrandDanfoss
ModelH1B 060
CategoryEngine
LanguageEnglish

Related product manuals