Open circuit requirements
H1 Bent Axis Motors may be used in Open Circuit (OC) applications.
Since loop flushing is typically not used in OC-applications it is essential to provide sufficient cooling
capacity. This can be done by motor case cross flushing.
The flow rate needs to be adjusted to the cooling demand.
The highest case drain outlet port must always be used for the return flow to the cooler or tank.
The motor case, the control system and the working lines connected to Port A and B must be kept full of
oil at all times, whether in a dynamic or static condition.
The plumbing must not allow the oil to drain down and be replaced with air in the control or rotating
group.
The minimum pressure in the inlet port and the outlet port, measured at gage ports MA and MB, must be
equal or higher as shown in the graphs Required inlet pressure diagrams (for cylinder block filling) on page
14.
Counter balance valves may be used to maintain the minimum pressure requirements. Also the Danfoss
Power Solutions Meter-in / Meter-out PVG technology may be used.
Check valves and sufficient charge pressure supply are also possible.
At no time shall the motor be allowed to operate above the rated speed limits. If flow limiter valves are
used, they must be selected accordingly. Select Motor controls which use the high loop system pressure
to shift the servo piston. This will ensure proper function under all conditions.
Valve blocks, such as counter balance valves attached to the inlet and/or outlet ports, must not interfere
with any part of the motor. A review of the outline drawings or appropriate 3D models must be
completed.
Fluid specifications
Fluid specifications
Features Unit
All sizes
Viscosity
Minimum intermittent
mm
2
/s
[SUS]
7 [49]
Recommended range
12-80 [66-366]
Maximum intermittent
1600 [7416]
Temperature range
1)2)
Minimum
°C
[°F]
-40 [-40]
Rated
104 [220]
Maximum intermittent
115 [240]
Cleanliness and Filtration
Required cleanliness per ISO 4406
-
22/18/13
Efficiency (charge pressure filtration)
β-ratio
β
15-20
= 75 (β
10
≥ 10)
Efficiency (suction / return line filtration)
β
35-45
= 75 (β
10
≥ 2)
Recommended inlet screen mesh size
µm 100 – 125
1)
At the hottest point, normally case drain port.
2)
Minimum: cold start, short term t<3 min, p<50 bar, n<1000 rpm.
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Technical specifications
©
Danfoss | December 2016 11037153 | BC00000043en-US1103 | 17

Table of Contents

Other manuals for Danfoss H1B 060

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss H1B 060 and is the answer not in the manual?

Danfoss H1B 060 Specifications

General IconGeneral
BrandDanfoss
ModelH1B 060
CategoryEngine
LanguageEnglish

Related product manuals