HOST MODE PROGRAMMING
30
4
4.4 ETHERNET
ETHERNET MODELS
PARAMETER TYPE SEL STRING DATA
ETHERNET SYSTEM
Status 1 1 ESC E A 0 = Disabled
1 = Enabled
DHCP Client 1 1 ESC E C 0 = Disabled
1 = Enabled
IP Address 2 ESC E D Length: 0 to 15
Subnet Mask 2 ESC E E Length: 0 to 15
Gateway Address 2 ESC E F Length: 0 to 15
DNS1 Address 2 ESC E G Length: 0 to 15
DNS2 Address 2 ESC E H Length: 0 to 15
DATA SOCKET
Status 1 1 ESC E I 0 = Disabled
1 = Enabled
Header String 2 ESC E J Length: 0 to 128
Terminator String 2 ESC E K Length: 0 to 128
Protocol 1 1 ESC E L 0 = TCP
1 = UDP
Port 0 ESC E M Range: 0 to 65535
Socket Type 1 1 ESC E N 0 = Server
1 = Client
Server Address 2 ESC E O Length: 0 to 256
Reading Phase ON
String
2 ESC E P Length: 1 to 128
Acquisition String 2 ESC E Q Length: 1 to 128
Reading Phase OFF
String
2 ESC E R Length: 1 to 128
IMAGE SOCKET
Status 1 1 ESC E S 0 = Disabled
1 = Enabled on Successful Decoding
2 = Enabled on Decoding Failure
3 = Always Enabled
Image Subsampling 1 1 ESC E T 0 = 1/1
1 = 1/4
2 = 1/16
3 = 1/64
Image Format 1 1 ESC E U 0 = BMP
1 = JPEG
2 = TIFF
JPG Quality (1-100) 0 ESC E V Range: 0 to 100
Protocol 1 1 ESC E W 0 = TCP
1 = UDP
Port 0 ESC E X Range: 0 to 65535
Type 1 1 ESC E Y 0 = Server
1 = Client
Server Address 2 ESC E Z Length: 0 to 256

Other manuals for Datalogic Matrix 210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 210 and is the answer not in the manual?

Datalogic Matrix 210 Specifications

General IconGeneral
BrandDatalogic
ModelMatrix 210
CategoryBarcode Reader
LanguageEnglish

Related product manuals