CHINA SENSIBLE CODE ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
223
China Sensible Code Set Length 1
Specifies one of the bar code lengths for "China Sensible Code Length Control" on page
222
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in
increments of 0001 (pad with zeroes).
See "
Set Length 1" on page 341 for detailed instructions on setting this feature.
China Sensible Code Set Length 2
This feature specifies one of the bar code lengths for "China Sensible Code Length Con-
trol" on page 222
. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to
7,827 characters in increments of 0001 (pad with zeroes).
See "
Set Length 2" on page 342 for detailed instructions on setting this feature.
Select China Sensible Code Length 1 Setting
$CCSL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
0001 = Length 1 is 1 Character
Select China Sensible Code Length 2 Setting
$CCSL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 is 7,827 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9600 and is the answer not in the manual?

Datalogic PowerScan PD9600 Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD9600
CategoryBarcode Reader
LanguageEnglish

Related product manuals