MODE SELECTION ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
265
Mode Selection
This feature allows the PowerScan 16K model to operate in one of two basic operative
modes:
Normal Mode data entered, either on the keypad or read via barcode, is trans-
mitted to the host once the enter key is pressed, following the configured format-
ting.
Quantity/Code Mode — Can be further configured. See the next sections for Qty/
Code operations.
Quantity Field
This feature defines the behavior of the scanner if no data is entered in the QTY field so
that it is left empty. Options are:
code is transmitted with default QTY (‘1’)
code is transmitted alone (without any quantity information)
code is discarded and an error beep is generated
Set Normal Mode
$CDISM00
$CDISM01
Set Qty Code Mode
Transmit code with default qty (‘1’)
$CPWEK00
$CPWEK01
Transmit Code only
Discard Code
$CPWEK02

Table of Contents