Enter/Exit Programming Mode Code 11
194 QuickScan™ I QM21X1 / QBT21X1
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Code 11 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC1LC00
Code 11 Length Control = Variable Length
$CC1LC01
Code 11 Length Control = Fixed Length
DEFAULT