Enter/Exit Programming Mode Code 93
224 QuickScan™ I QM21X1 / QBT21X1
Code 93 Check Character Transmission
Enables/disables transmission of an optional Code 93 check character.
Code 93 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Code 93 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC9CT00
Code 93 Check Character Transmission = Disable
$CC9CT01
Code 93 Check Character Transmission = Enable
DEFAULT
$CC9LC00
Code 93 Length Control = Variable Length
$CC9LC01
Code 93 = Fixed Length
DEFAULT

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan I QBT21X1 and is the answer not in the manual?

Datalogic QuickScan I QBT21X1 Specifications

General IconGeneral
TypeHandheld
Humidity5% to 95% non-condensing
ConnectivityBluetooth
Scanning TechnologyImager
InterfaceUSB, RS-232
Scan Rate400 scans/sec
Light SourceLED
Resolution4 mil
Supported BarcodesUPC, EAN, Code 39, Code 128
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 70°C
Drop Specification1.5 m drop resistance
Power SupplyRechargeable battery
Cable Length2 m
Battery LifeUp to 30, 000 scans per charge
Decode Capability1D barcodes

Summary

Chapter 2 Setup

Setting Up the Reader

Outlines steps for cordless models: configuring base station, charging batteries, linking, and selecting interface type.

Host Connection

Guides on verifying cable compatibility and connecting the reader to the host device, including Wedge 'Y' cables.

Linking the Reader to a Base Station

Details linking RF devices, including unlinking previous bases and checking link status via tones/LEDs.

Linking a BT Reader to a PC

Explains how to link a Bluetooth reader to a PC in Server Mode (BT Slave Mode) via drivers and discovery.

Charging the Battery Pack

Explains inserting the reader into the base for charging and alternative charging via micro-USB.

Battery Safety

Provides critical safety warnings for handling, charging, and using Lithium-ion battery packs to prevent hazards.

Replacing the Battery Pack

Step-by-step guide on how to remove and mount a battery pack using a screwdriver and the captive screw.

Chapter 3 Interfaces

Interface Selection

Lists supported host interfaces for reader models: USB (KBD, COM STD, OEM) and RS-232/Keyboard Wedge.

Configuring the Interface

Explains scanning interface type bar codes and proceeding to corresponding chapters for configuration.

Chapter 4 Configuration Using Bar Codes

Using the Programming Bar Codes

Explains how to use programming bar codes, including entering/exiting Programming Mode and scanning parameters.

Datalogic Aladdin™ Utility

Describes the Aladdin utility for PC-based configuration, software upgrades, and creating configuration bar codes.

Global Interface Features

Host Commands — Obey/Ignore

Specifies whether the reader obeys or ignores host commands, except for essential service functions.

RS-232 ONLY Interface

Baud Rate

Sets the data transmission speed per second to match the host device's baud rate setting.

Data Bits

Configures the number of data bits (7 or 8) for the ASCII protocol, affecting sending and receiving data.

Stop Bits

Sets the number of stop bits (1 or 2) to mark the end of transmission and prepare for the next character.

Keyboard Interface

COUNTRY MODE

Selects the country/language supported by the keyboard for USB Keyboard and Keyboard Wedge interfaces.

USB-OEM Interface

Data Format

GLOBAL PREFIX/SUFFIX

Allows adding up to 20 ASCII characters as a prefix or suffix to bar code data.

Reading Parameters

Double Read Timeout

Sets minimum time between reads of the same label to prevent double reads.

Scanning Features

Scan Mode

Selects the scan operating mode, including Trigger Single, Trigger Hold, Flashing, Always On, and Autosense.

Symbologies

UPC-A

Configuration options for the UPC-A symbology, including enable/disable and check character transmission.

UPC-E

Configuration options for the UPC-E symbology, including enable/disable and check character transmission.

EAN 13

Configuration options for the EAN 13 (Jan 13) symbology, including enable/disable and check character transmission.

EAN 8

Configuration options for the EAN 8 (Jan 8) symbology, including enable/disable and check character transmission.

Code 39

Configuration options for the Code 39 symbology, including enable/disable and check character settings.

Code 128

Configuration options for the Code 128 symbology, including enable/disable and expansion to Code 39.

Code 11

Configuration options for the Code 11 symbology, including enable/disable and check character settings.

WIRELESS FEATURES

WIRELESS BEEPER FEATURES

Configures beeper behavior for RF operation, including transmission beeps and frequency.

CONFIGURATION UPDATES

Ensures reader and base station configurations stay synchronized automatically.

BATCH FEATURES

Specifies whether to store labels in handheld when disconnected: Disabled, Automatic, or Manual.

DIRECT RADIO AUTOLINK

Enables or disables linking a wireless handheld to a base station without scanning an Unlink label first.

BLUETOOTH-ONLY FEATURES

Configuration options specific to Bluetooth models, including RF address stamping and delimiter characters.

Source Radio Address Transmission

Enables/disables transmitting source radio address info to host and specifies its position.

BT SECURITY FEATURES

Settings for BT security, including enabling security mode and setting a PIN code.

BT Security Mode

Enables or disables authentication and encryption of the BT link.

STAR Radio Protocol Timeout

Sets wait time before transmission between handheld and Base Station is considered failed.

STAR Radio Transmit Mode

Specifies the transmission protocol for Star communications (ACK options).

Chapter 5 Message Formatting

Message Formatting

Details rules for Host-to-Base messages, including address stamping, character limits, and CR termination.

Keyboard Wedge

Data Editing

Data Editing Overview

Explains how to send additional info with bar codes, forming a 'message string' with features like Prefix, Label ID, AIM ID.

Global Prefix/Suffix

Allows adding up to 20 ASCII characters as a prefix or suffix to bar code data.

Symbology Settings

Decoding Levels

Explains configuring decoder aggressiveness for symbologies, from conservative to aggressive.

RF Features

Automatic Configuration Update

Ensures reader and base station configurations stay synchronized automatically.

BT Pin Code

Specifies the 4-character or 16-character PIN code for BT authentication and encryption.

LED and Beeper Indications

Error Codes

Lists LED flashes/beep codes associated with errors, including corrective actions.