4. R
otate the storage processor extraction levers upwards until the storage processor retracts fully into place and the storage
processor extractors snap into place (2).
NOTE:
The extractors snapping into place is not guaranteed. Press the release buttons, and then swing the extractors
into place. Then, let go the release buttons. If testing when the SP is fully seated, attempt to swing out the extractors
without releasing them.
Verify the fans
Steps
1. Enter the enclosure show fans command to check the status of the enclosure fans.
# e
nclosure show fans 1
Enclosure Description Level Status
--------- ----------- ------ ------
1 FAN 0A medium OK
FAN 0B medium OK
FAN 1A medium OK
FAN 1B medium OK
FAN 2A medium OK
FAN 2B medium OK
FAN 3A medium OK
FAN 3B medium OK
FAN 4A medium OK
FAN 4B medium OK
FAN 5A medium OK
FAN 5B medium OK
--------- ----------- ------ ------
Check the Status column to confirm that all of the fans in Enclosure 1 are OK.
2. Enter the alerts show current command and confirm that the system has cleared the alert for the failed fan. It may
take one to two minutes after the fan replacement before the system clears the alert.
# a
lerts show current
No active alerts.
14 Field Replaceable Units

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Data Domain DD6300 and is the answer not in the manual?

Dell Data Domain DD6300 Specifications

General IconGeneral
BrandDell
ModelData Domain DD6300
CategoryNetwork Hardware
LanguageEnglish

Related product manuals