Enter the i
pmi user list command to verify the IPMI users.
# i
pmi user list
Name User Id Privilege
------ ------- -------------
ipmi2 3 ADMINISTRATOR
ipmi1 2 ADMINISTRATOR
------ ------- -------------
Total users: 2
9. Enter the ipmi user change command to change the password of an IPMI user if needed:
# i
pmi user change ipmi1 password
10. Because the system disks and Fibre Channel I/O modules are moved from the old chassis to the new chassis, no changes are
required for drive mappings or access groups. If such changes are required, however, use the details captured in Preliminary
and troubleshooting steps on page 53 to confirm FC I/O configuration. Refer also to the Data Domain System Controller
Upgrade Guide for more information.
Bring HA back online
About this task
For HA systems, bring the HA configuration back online.
Steps
1. Run the ha online command on the standby node to bring the HA configuration back online.
2. For HA systems that were failed over to the standby node before the component replacement, optionally fail the system
back to the original active node. Run the ha status command to verify that the HA pair can failover and the ha
failover on the current active node to restore the original active node.
Field Replaceable Units 59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Data Domain DD6300 and is the answer not in the manual?

Dell Data Domain DD6300 Specifications

General IconGeneral
BrandDell
ModelData Domain DD6300
CategoryNetwork Hardware
LanguageEnglish

Related product manuals