Verify NVRAM
S
teps
1. Enter the enclosure show chassis command to check the battery and NVRAM chassis status.
NOTE:
The NVRAM battery might take up to 1.5 hours to get fully (100%) charged depending on how discharged the
NVRAM battery is at the time of the installation. However the filesystem is enabled when the battery capacity is above
80%, which should take a shorter time.
2. E
nter the system show hardware command to check information about the NVRAM module.
3. Enter the system show nvram command to check battery and NVRAM status.
# s
ystem show
nvram
NVRAM Cards:
Card Component Value
---- ----------------------- -----------------------------------------
1 Slot 0
Firmware version 0.0.78
Memory size 7.93 GiB
Errors 0 memory (0 uncorrectable), 0 PCI, 0 controller
Flash controller Errors 0 Cfg Err, 0 PANIC, 0 Bus Hang, 0 Bad Blk Warn,
0 Bkup Err, 0 Rstr Err
Board temperature 39 C
CPU temperature 48 C
Number of batteries 1
---- ----------------------- -------------------------------------------
NVRAM Batteries:
Card Battery Status Charge Charging Time To Temperature Voltage
Status Full Charge
---- ------- ------ ------ -------- ----------- ---------- -----
1 1 ok 95 % enabled 0 mins 37 C 4.044 V
---- ------- ------ ------ -------- ----------- ----------- -------
4. Enter the enclosure show misconfiguration command to verify if the NVRAM is in the correct slot.
# e
nclosure show misconfiguration
Memory DIMMs:
No misconfiguration found.
IO Cards:
No misconfiguration found.
CPUs:
No misconfiguration found.
Disks:
No misconfiguration found.
5. Run the alerts show current or alerts show current-detailed command to check alert information about
battery and NVRAM card status.
6. For HA systems that were failed over to the standby node before the component replacement, run the ha online
command on the standby node to bring the HA configuration back online.
Field Replaceable Units 23

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Data Domain DD6300 and is the answer not in the manual?

Dell Data Domain DD6300 Specifications

General IconGeneral
BrandDell
ModelData Domain DD6300
CategoryNetwork Hardware
LanguageEnglish

Related product manuals