EasyManuals Logo

Dell EMC PowerEdge R750xs 60KKP User Manual

Dell EMC PowerEdge R750xs 60KKP
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Figure 29. Removing the cooling fan cage
Next steps
1. Replace the cooling fan cage.
Installing the cooling fan cage
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
CAUTION:
Ensure that the cables inside the system are correctly installed and retained by the cable
retention bracket before installing the cooling fan cage assembly. Incorrectly installed cables may get
damaged.
2. Follow the procedure listed in Before working inside your system.
3. If installed, remove the air shroud.
Steps
1. Align the guide rails on the cooling fan cage with the standoffs on the system.
2. Lower the cooling fan cage into the system.
3. Lower the blue release levers to lock the cooling fan cage into the system.
Installing and removing system components
41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC PowerEdge R750xs 60KKP and is the answer not in the manual?

Dell EMC PowerEdge R750xs 60KKP Specifications

General IconGeneral
Form Factor2U rack server
ProcessorUp to 2 x Intel Xeon Scalable processors, up to 32 cores per processor
MemoryUp to 2TB DDR4, 3200MT/s, 16 DIMM slots
StorageUp to 12 x 3.5" SAS/SATA (HDD/SSD)
RAID ControllerPERC H745, H755, HBA355i
Network1GbE, 10GbE, 25GbE
Power Supply1100W