57
8514-311-001 REV PR
Symptom Probable Cause Suggested Remedy
Tumbler Does not turn Control Check that Control Display shows time available for
drying.
Loading Door Check that Loading Door is completely closed.
Lint Compartment Door Check that Lint Compartment Door is completely closed.
Drive Belts Check drive belts for excessive wear. Replace as needed.
Control Transformer
Primary Fusing
Check the fuse (50Hz: 2.0A) for continuity. If no
continuity, replace the fuse.
Control Transformer
Secondary Fusing
Check the fuse (50Hz: 2.5A) for continuity. If no
continuity, replace the fuse.
Tumbler Turns, but no
burner flame is present
Gas shut-off valve Make sure gas shut-off valve is in the open position
Ignition Module Follow the procedure for checking the ignition cycle
listed in Dryer Ignition section of this manual.
Check the ignition control fuse (50Hz: 1.5A) for
continuity. If no continuity, replace the fuse.
Slow Drying Control Check that proper Temperature setting is chosen.
Lint Screen
Clean Lint Screen
Air flow Restrictions/
Make-up Air
Follow installation guidelines for static back pressure and
make-up air.
Exhaust Check exhaust for obstructions, follow installation
guidelines.
F1 or F2 Fault Code
displayed on control
Temperature Sensor See Dryer Fault Code section of this manual or contact
Dexter agent for assistance.
F3 Fault Code displayed on
control
Control Error See Dryer Fault Code section of this manual or contact
Dexter agent for assistance.
F4 or F5 Fault Code
displayed on control
Drying Temperature
Error
See Dryer Fault Code section of this manual or contact
Dexter agent for assistance.
Table 7-6 Servicing and Troubleshooting Table