90030500B Troubleshooting Page 191
EBI 3...............none
Press "?" for diagnostics menu
or carriage return to continue booting
3.
When you press
?
, the diagnostics menu appears, as shown below. This lists the
eight tests that you can select. These tests perform diagnostic checks on hardware
within PortServer II.
DIAGNOSTICS MENU---
A = All tests (except 9)
1 = Front panel light test
2 = RAM test
3 = Timer and real-time clock test
4 = EBI internal loopback test
5 = EBI external loopback test
6 = Ethernet internal loopback test
7 = Ethernet external loopback test
8 = Flash RAM test
9 = Watchdog test
C = Configure boot
T = Set date & time
Ethernet address: 12:34:56:78:9A:BC
B = Reboot
4. To start any test, press the appropriate test number. See
Basic Test Descriptions
later in this chapter for information on the individual tests.