Page 206 Troubleshooting 90030500B
unknown DLCI
The number of received frames with a DLCI indicating a PVC that is not configured.
LMI unknown IE
The number of Information Elements in received LMI packets that had an unrecog-
nized type code.
LMI unknown report
The number of LMI reports received that had an unrecognized type code.
status requests
The number of LMI status requests sent.
status responses
The number of LMI status responses sent.
rcvd sequence number
The last sequence number received.
updates or async status
The number of updates or async status reports received. The value shown depends on
the type of LMI used.
full status requests
The number of full status requests sent.
full status responses
The number of full status requests received.
sent sequence number
The last sequence number sent.
frames/octets sent within CIR
The number of frames/octets sent within the Committed Information Rate.
frames/octets sent beyond CIR
The number of frames/octets sent beyond the Committed Information Rate.