B - 15
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A With Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 to 40% 55 to 65%
Freezer Temperature 0° to 4°F
-18° to -16°C
-1° to 3°F
-18° to -16°C
Refrigerator Temperature 34° to 39°F
1° to 4°C
34° to 39°F
1° to 4°C
Low Side Pressure (
cut-in) 5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (
cut-out) -2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure (
Last 1/3 of cycle) 90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (Last 1/3 of cycle) 120 to 150 130 to 160
Amps (Running) 1.2 to 1.5 1.2 to 1.5
Base Voltage 115 VAC 115 VAC
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-in Cut-out Watts Ohms
23' & 26' 25°F
-4°C
47°F
8°C
450 30
Mechanical Timer - Defrost 30 Minutes Every 8 Hours of Compressor Run Time
Adaptive Defrost Control - Defrost Up To 30 Minutes every 6 - 72 Hours
CONDENSER FAN MOTOR
Watts RPM Amps
7 1100 CW Opposite Shaft .1 Running
ICE MAKER SPECIFICATIONS
Electrical 115 Volts 60 Hertz
Thermostat Opens at 48°F (9°C) Closes at 15°F (-9°C)
165