92
USAGE
SPECIFICATIONS
Temperature limits +14°F to +122°F (-10°C to +50°C)
0% to 95%RH (non-condensing) for +32°F to +122°F (0°C to +50°C)
Storage with batteries -4°F to 131°F (-20°C to +55°C) for less than 1 month
Storage without batteries -4°F to +140°F (-20°C to +60°C)
Enclosure rating IP51 (front)
Shock Passes the 1-meter drop test onto concrete
General guidelines • Only use new, original parts.
• Do not recharge the battery in hazardous areas.
• Have repairs done by only qualified personnel.
• Charge or power using only the Field Communicator power
supply/charger.
CONNECTION
SPECIFICATIONS
HART and fieldbus
communication terminals
Three 4mm banana plugs (one common terminal to both HART and
F
OUNDATION fieldbus.)
Connection types IrDA port
± 15 degrees recommended maximum angle between the 475
interface and adapter or PC.
18 in. recommended maximum distance between the 475 interface
and adapter or PC.
Bluetooth interface
The Bluetooth Interface is a licensed option for the 475 Field
Communicator. If your 475 is not licensed for Bluetooth, it does not
have a Bluetooth radio.To use Bluetooth you need an approved
adapter using the Windows Bluetooth software and drivers (stack)
included with Windows XP Professional Service Pack 2 or 3, Windows
Vista Business Service Pack 1, or Windows 7 Professional. The
adapter should be plug-and-play if no other Bluetooth software or
drivers were installed on your PC. The Easy Upgrade Utility cannot
communicate with an adapter using third-party drivers. See
www.fieldcommunicator.com or the readme file for more information.
30 feet (10 meters) recommended maximum distance between the
475 and a Bluetooth adapter attached to a PC.