Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
210 Affinity User Guide
www.controltechniques.com Issue Number: 5
Figure 11-41 SM-I/O 32 logic diagram
SM-I/O 32 parameters
*See trip SLX.Er,
Automation (I/O Expansion) module category on page 257
.
X.XX
X.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default setting
X.3y*
x(-1)
x(-1)
X.1y
X.0y**
I/O state
Output
select
Source/
destination
I/O invert
X.2y
Any unprotected
parameter
Parameter Range(Ú) Default(Ö)Type
x.01 Solutions Module ID code 0 to 599 208 RO Uni PT US
x.02 Solutions Module main software version 0.00 to 99.99 99.00 RO Uni NC PT
x.03 Digital I/O 3 state
OFF(0) or On(1) OFF (0)
RO Bit NC PT
x.04 Digital I/O 4 state RO Bit NC PT
x.05 Digital I/O 5 state RO Bit NC PT
x.06 Digital I/O 6 state RO Bit NC PT
x.07 Digital I/O 7 state RO Bit NC PT
x.08 Digital I/O 8 state RO Bit NC PT
x.09 Digital I/O 1 state RO Bit NC PT
x.10 Digital I/O 2 state RO Bit NC PT
x.11 Digital I/O 1 invert RW Bit US
x.12 Digital I/O 2 invert RW Bit US
x.13 Digital I/O 3 invert RW Bit US
x.14 Digital I/O 4 invert RW Bit US
x.15 Digital I/O 5 invert RW Bit US
x.16 Digital I/O 6 invert RW Bit US
x.17 Digital I/O 7 invert RW Bit US
x.18 Digital I/O 8 invert RW Bit US
x.20 Digital I/O read word 0 to 255 0 RO Uni NC PT
x.21 Digital I/O 1 source/destination
Pr 0.00 to Pr 50.99 Pr 0.00
RW Uni DE PT US
x.22 Digital I/O 2 source/destination RW Uni DE PT US
x.23 Digital I/O 3 source/destination RW Uni DE PT US
x.24 Digital I/O 4 source/destination RW Uni DE PT US
x.25 Digital I/O 5 source/destination RW Uni DE PT US
x.26 Digital I/O 6 source/destination RW Uni DE PT US
x.27 Digital I/O 7 source/destination RW Uni DE PT US
x.28 Digital I/O 8 source/destination RW Uni DE PT US
x.29 Digital I/O 4 output select
OFF(0) or On(1)
On(1) RW Bit PT US
x.31 Digital I/O 1 output select
OFF (0)
RW Bit US
x.32 Digital I/O 2 output select RW Bit US
x.33 Digital I/O 3 output select
RW Bit US
x.43 First update method direction register
Pr 0.00 to Pr 50.99 Pr 0.00
RW Uni DE PT US
x.47 Fast update method read register RW Uni DE PT US
x.48 Fast update method write register RW Uni PT US
x.50 Solutions Module error status* 0 to 255
RO Uni NC PT
x.51 Solutions Module software sub-version 0 to 99
RO Uni NC PT
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save